ȨÀ¸·Î email »çÀÌÆ®¸Ê
  ·Î°í  
  º´¿ø¼Ò°³
 
 
 
   
ŸÀÌÆ²
HOME > À¯¹æ¾ÏŬ¸®´Ð > ¹Ì¼¼¼®È¸È­ Á¶Á÷°Ë»ç  
 
¼®È¸È­(calcification) ¸ð¾ç
(¹Ì±¹ ACR : Ameraican College of Radiology ºÐ·ù¹ý)
¹Ì¼¼¼®È¸È­(Microcalcification)ÀÇ ºÐÆ÷¿¡ µû¸¥ Á¶Á÷°Ë»ç
¹Ì¼¼ ¼®È¸È­ÀÇ ºÐÆ÷ ¾ç»ó¿¡ µû¶ó °¡Äª random MMT(·£´ý¸¾¸ðÅèmammotome, directional vaccum-assisted biopsy), targeted MMT(Ÿ°Ù¸¾¸ðÅè) ȤÀº localization MMT(À§Ä¡ÀâÀ̸¾¸ðÅè) ¹æ½ÄÀ» ÀÌ¿ë ÇÒ ¼ö ÀÖ´Ù.
 
1) random MMT (·£´ý¸¾¸ðÅè)
¹Ì¼¼ ¼®È¸È­°¡ À¯¹æ Àüü¿¡ ±¤¹üÀ§ÇÏ°Ô ÆÛÁ®ÀÖ°í ÃÊÀ½ÆÄ °Ë»ç¿¡¼­ ³ªÅ¸³ª´Â ¼Ò°ßÀÌ ¾øÀ» °æ¿ì [±×¸²D]
2) targeted MMT (Ÿ°Ù¸¾¸ðÅè)
¹Ì¼¼ ¼®È¸È­°¡ ±¤¹üÀ§ÇÏ°Ô ºÐÆ÷ Çϰųª ÇÑ Áö¿ª¿¡ Ä¡¿ìÃÄ ºÐÆ÷ Çϸ鼭 ÃÊÀ½ÆÄ °Ë»ç¿¡¼­ ³¶Á¾ ȤÀº ³¶Á¾¼º º¯È­ µîÀÇ
À¯¼Ò°ßÀÌ µ¿¹Ý µÇ´Â °æ¿ì [±×¸²B, C]
3) localization MMT (À§Ä¡ÀâÀ̸¾¸ðÅè)
¹Ì¼¼ ¼®È¸È­°¡ ¹ÐÁý µÇ¾î ºÐÆ÷¸¦ º¸À̰í ÃÊÀ½ÆÄ °Ë»ç¿¡¼­ ³ªÅ¸³ª´Â ¼Ò°ßÀÌ ¾ø´Â °æ¿ì [±×¸²A, B]
 
¹Ì¼¼ ¼®È¸È­ÀÇ ºÐÆ÷ ¾ç»ó (¹Ì±¹ ACR : Ameraican College of Radiology ºÐ·ù¹ý)
Á¶Á÷°Ë»çÀÇ Á¾·ù
1) random MMT (·£´ý¸¾¸ðÅè)
À¯¹æÃÔ¿µ »ó ¹Ì¼¼¼®È¸È­°¡ °¡Àå ¸¹ÀÌ ¹ÐÁýµÈ ¿µ¿ª (quadrant)À» È®ÀÎÇÑ ÈÄ ±× ¿µ¿ªÀÇ
Á߽ɿ¡ skin markingÀ» ÇÑ ÈÄ 8G(°ÔÀÌÁö) ¸¾¸ðÅè probe¸¦ »ç¿ëÇÏ¿©
ÁÖÀ§ÀÇ Á¶Á÷À» 360µµ ¹æÇâ¿¡¼­ ÃæºÐÈ÷ ¶¼¾î³½´Ù.
±× ÈÄ °ËüÀ¯¹æÃÔ¿µ¼ú(specimen mammography)·Î ¹Ì¼¼¼®È¸È­°¡ Æ÷ÇÔ µÇ¾ú´ÂÁö
È®ÀÎÇÑ´Ù.
2) targeted MMT (ŸÄϸ¾¸ðÅè)
À¯¹æÃÔ¿µ »ó ¹Ì¼¼ ¼®È¸È­ À§Ä¡¿Í ÃÊÀ½ÆÄ °Ë»ç¿¡¼­ÀÇ º´º¯ÀÇ À§Ä¡°¡ ÀÏÄ¡ÇÏ´ÂÁö¸¦
È®ÀÎ ÇÑ ÈÄ º´º¯À» targetÀ¸·Î ÁÖÀ§ÀÇ Á¶Á÷À» 360µµ ¹æÇâ¿¡¼­ ÃæºÐÈ÷ ¶¼¾î³½´Ù.
±× ÈÄ °ËüÀ¯¹æÃÔ¿µ¼ú·Î È®ÀÎÇÑ´Ù.
3) localization MMT (À§Ä¡ÀâÀ̸¾¸ðÅè)
localization ½ÃÀÛ Àü¿¡ °Ë»ç Ãø À¯¹æÀÇ CC, ML ÃÔ¿µÀÌ ¿ä±¸µÈ´Ù.
±âº» À¯¹æ ÃÔ¿µÀ» ±âÁØÀ¸·Î Á¢±ÙÇØµµ µÇ³ª MLO ¿µ»óÀÌ lateral view ¿¡ ºñÇØ
À§Ä¡ÀÇ ¿Ö°îÀÌ ÀÖÀ¸¹Ç·Î °¡´ÉÇϸé lateral view·Î À§Ä¡¸¦ ¼±Á¤ÇÏ¿© ÃÖ¼ÒÇÑ º´º¯¿¡
°¡±õ°Ô Á¢±ÙÇÏ´Â °ÍÀÌ ÁÁ´Ù.
[º´º¯ÀÇ À§Ä¡¿¡ µû¸¥ Á¢±Ù ¹æ¹ý]
a. À¯¹æÀÇ »óºÎ¿¡ À§Ä¡ÇÏ´Â °æ¿ì Craniocaudal·Î Á¢±Ù
b. º´º¯ÀÌ ¿ÜÃø¿¡ À§Ä¡Çϰí ÇϺο¡ ÀÖ´Ù¸é lateromedial·Î Á¢±Ù
c. º´º¯ÀÌ ³»Ãø¿¡ À§Ä¡Çϰí ÇϺο¡ ÀÖ´Ù¸é mediolateral·Î Á¢±Ù
 
À¯¹æÀ» localization paddle ·Î ¾Ð¹ÚÇϴµ¥ À̶§ ¾Ð¹Ú paddleÀÇ fenestrated ºÎºÐ ¾ÈÀ¸·Î º´º¯ÀÌ Æ÷ÇԵǾî¾ß ÇÑ´Ù.
°Ë»ç°¡ ³¡³¯ ¶§±îÁö ȯÀÚ´Â ¾Ð¹Ú »óÅ¿¡ ÀÖ¾î¾ß ÇϹǷΠóÀ½ºÎÅÍ È¯ÀÚ¿¡°Ô ÇùÁ¶¸¦ ±¸Çϰí ÃÖ´ëÇÑ ¾Ð¹Ú½Ã°£À»
ÁÙÀ̵µ·Ï ³ë·ÂÇÑ´Ù.
¾Ð¹Ú ÈÄ ¿µ»ó¿¡¼­ º¸ÀÌ´Â º´º¯ÀÇ À§Ä¡¸¦ paddle À§ÀÇ ÁÂÇ¥¸¦ ÀÌ¿ëÇÏ¿© ÇǺο¡ Ç¥½ÃÇÑ´Ù.
Ç¥½ÃÇÑ °÷¿¡ localization needle(spring hook wire¸¦ »« needle¸¸, 21G X 9cm)À» ÇÇºÎ¿Í Á÷°¢ÀÌ µÇµµ·Ï
»ðÀÔ ½ÃŲ ÈÄ ÃÔ¿µÀ» ÇÏ¿© º´º¯¿¡ needleÀÌ Á¤È®È÷ À§Ä¡Çß´ÂÁö È®ÀÎÇÑ´Ù.
needleÀÇ À§Ä¡°¡ ºÎÁ¤È®ÇÏ´Ù¸é needleÀÌ º´¼Ò¿¡ À§Ä¡Çϵµ·Ï º¸Á¤ÇÑ´Ù.
Á¤È®È÷ needleÀÌ À§Ä¡ÇÏ¿´´Ù¸é ¾Ð¹ÚÀ» Ç®°í ´Ù¸¥ ¹æÇâ¿¡¼­ ÃÔ¿µÇÏ¿© 2Â÷¿øÀûÀ¸·Î È®ÀÎÇÑ´Ù.
È®ÀÎ ÈÄ needleÀÇ À§Ä¡°¡ Á¤È®ÇÏ´Ù¸é ¾Ð¹ÚÀ» Ç®°í ȯÀÚÀÇ À¯¹æÀ» ¿ø·¡ »óÅ·ΠÀ¯Áö½ÃŲ´Ù.
needle¿¡ ÇǺΠǥ¸éÀÇ ±íÀ̸¦ Áö¿öÁöÁö ¾Ê´Â ÆæÀ¸·Î Ç¥½ÃÇÏ¿© µÎ¸é position º¯°æ ½Ã ¹ß»ý ÇÒ ¼ö ÀÖ´Â needleÀÇ
À̵¿À» ¹æÁöÇÑ´Ù. ȯÀÚ¸¦ ¸¾¸ðÅèÀ» ½ÃÇàÇÒ ¹æÀ¸·Î ¿Å±â°í ÃÊÀ½ÆÄ·Î ¹Ù´ÃÀÇ ³¡(tip)À» È®ÀÎÇÏ¿© skin markingÀ»
ÇÑ ÈÄ ¹Ù´ÃÀÇ ³¡À» ¸ñÇ¥·Î ¸¾¸ðÅè probe¸¦ »ðÀÔÇϰí probe ÁÖÀ§ 360µµ ¹æÇâ¿¡¼­ 8~12 ÀýÆí(250~310 mg/piece,
ÃÑ 2,000 mg~3,720 mg) Á¤µµÀÇ ÃæºÐÇÑ Á¶Á÷À» ¶¼¾î³½´Ù. ±× ÈÄ °ËüÀ¯¹æÃÔ¿µ¼ú·Î È®ÀÎÇÑ´Ù
Á¶Á÷°Ë»ç °á°ú
- ÃßÀû °üÂûÀÌ °¡´ÉÇϰí Ãß°¡ÀûÀÎ º´º¯ÀÇ º¯È­°¡¾ø´Ù.
- ½Ã¼ú ÈÄ ´Ü±â³ª Àå±âÀûÀÎ ÇÕº´ÁõÀÌ ¾ø´Ù.
- ¿Ü°úÀû »ý°Ë¼ú°ú ºñ±³ÇÏ¿© »óó°¡ ÀÛ°í À¯¹æÀÇ º¯Çü ¾øÀÌ ¼º°øÀûÀ¸·Î Á¶Á÷°Ë»ç¸¦ ÇÒ ¼ö ÀÖ´Ù.
- ±ºÁý¼º ¹Ì¼¼ ¼®È¸È­ÀÇ °æ¿ì 10°³ ³»¿ÜÀÇ ¹Ì¼¼ ¼®È¸È­´Â ÀüºÎ Á¦°Å °¡´ÉÇÏ´Ù.
Á¦ÇÑÁ¡
localization MMT(À§Ä¡ÀâÀÌ ¸¾¸ðÅè)À» ÇÒ °æ¿ì ¹Ì¼¼ ¼®È¸È­°¡ ÇǺο¡ ±ÙÁ¢ ÇØ ÀÖ´Â °æ¿ì needleÀ» ²È¾ÒÀ» ¶§
ÁöÅÊÇÒ ¼ö°¡ ¾ø¾î¼­ ÃÊÀ½ÆÄ À¯µµ ÇÏ ¸¾¸ðÅè »ý°ËÀ» ÇÒ ¼ö°¡ ¾ø¾ú´Ù.
ÀÌ·± °æ¿ì¿¡´Â ÀÔüÁ¤À§»ý°Ë(stereotactic biopsy) ¹æ½ÄÀ» ÃßõÇÑ´Ù.
°á ·Ð
ÃÊÀ½ÆÄ À¯µµ ÇÏ ¸¾¸ðÅèÀ» ÀÌ¿ëÇÏ¿© È¿°úÀûÀ¸·Î ¹Ì¼¼ ¼®È¸È­ÀÇ »ý°ËÀ» ¼öÇà ÇÒ ¼ö ÀÖ¾úÀ¸¸ç ´õ ¸¹Àº Áõ·Ê¿¡ ´ëÇØ Àå±âÀûÀÎ °üÂû°ú ºÐ¼®ÀÌ ÇÊ¿äÇÏ´Ù.
·Î°í º´¿ø¼Ò°³ ã¾Æ¿À½Ã´Â±æ ¿Â¶óÀλó´ã½Ç »çÀÌÆ®¸Ê    
copy